Customization: | Available |
---|---|
Type: | Metal Film Displacement Sensors |
Output Signal Type: | Analog Type |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GF series split LVDT displacement sensor(crack meter)is specially used for on-line monitoring of crack depth,width and opening and closing degree in bridge,tunnel,building,concrete pavement and other civil engineering projects.The sensor is powered by 12-24V DC,with fisheye heads at both ends.The electronic circuit is sealed in 304 stainless steel metal tube,which can be used in open air or in humid environment for long-term stable work.Output standard 0-5V,0-10V voltage signals which can be used by computer or PLC;4-20mA current signal;RS485 digital signal
Power supply | 12-24 VDC | |
Working current: | Voltage output type, power supply current≤12mA; Two wire current output type, supply current 4-20mA |
|
Displacement range: | GF25:0-5m GF50:0-10mm GF125:0-25mm GF250:0-50mm GF500:0-100mm GF1250:0-250mm GF2500:0-500mm |
|
Output signal | 0-5V;0-10V;4-20mA;RS485 digital signal | |
Linear error | Analog signal output:0.25% FS Digital signal output:0.1% FS |
|
Repetition error | ≤1um | |
Resolution | ≤O.1um | |
Dynamic characteristi | 10Hz | |
Measuring force | 80g | |
Operating temperature | -25°C --- +85 °C | |
Impact resistance | 250G/11 ms | |
Vibration tolerance | 10g/2KHz | |
Temperature coefficie | Zero point≤0.01/°C;Sensitivity ≤025/°C |